EXAMPLE REPORT

The detail behind the data.

This demonstration shows the style of annotated findings you can expect. Every site and dataset is different. All figures and findings below are fictional.

FICTIONAL EXAMPLE — NOT A REAL CLIENT OR INSTALLATION

Solar PV performance overview

Illustrative UK commercial rooftop array · Installed capacity: 100 kWp DC · Review period: 12 months · Data source: invented monitoring exports

ACTUAL GENERATION85.4 MWh
TYPICAL-YEAR BENCHMARK91.6 MWh
SCREENING VARIANCE−6.8%

Generation was below the illustrative typical-year benchmark. This is a screening observation, not a verified energy loss. Without actual-period irradiance and reliable system availability data, the difference cannot be confidently attributed to equipment performance.

Annual generation compared with benchmark

The example below illustrates a more significant variation in June than in adjacent months, making it a sensible period to investigate first.

MonthActual (MWh)Benchmark (MWh)Variance
April9.19.5−4.2%
May10.711.5−7.0%
June9.812.2−19.7%
July11.812.5−5.6%
↳ Annotation 01: June generation variance

The June shortfall is larger than the surrounding months. Investigate actual weather conditions, inverter availability and monitoring data completeness before concluding there is a technical fault.

Data-quality note: Expected generation above represents a fictional typical year, not measured actual-period irradiation. No performance ratio or verified financial loss is calculated.

ArrayBrief · Fictional report demonstration · Page 1 of 2
FICTIONAL EXAMPLE — NOT A REAL CLIENT OR INSTALLATION

What to investigate next

Clear, proportionate findings help you decide whether further work is worth commissioning.

Finding A — June generation difference

Priority: Investigate

A typical-year comparison shows a larger shortfall in June. This could reflect actual weather, curtailment, equipment downtime, clipping-model differences or incomplete monitoring records. The data supplied does not distinguish these causes.

Finding B — Inverter-level variation

If inverter-level output data is available, compare specific yield (kWh/kWp) only between systems with comparable orientation, shading and operating conditions. Differences should be treated as leads for investigation, not fault confirmation.

Recommended actions

  1. Obtain June's daily generation and alarm history, including any missing-data periods.
  2. Check actual-period irradiance or local weather observations against the benchmark assumptions.
  3. Compare like-for-like inverter yields, only where orientation and installed capacity permit.
  4. Refer any suspected electrical or equipment fault to a suitably qualified O&M provider.

Important scope limitations

This remote review provides an interpretation of existing operating data. It does not include site inspection, independent verification of metering, electrical testing, electrical safety certification, guaranteed performance estimates or real-time alarm response.

Actual client reports would include evidence sources, date ranges, data quality notes and findings tailored to the installation.

ArrayBrief · Fictional report demonstration · Page 2 of 2